ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector   Our stock number: 392205

ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector

Click on picture below for larger version
ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector
ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak DetectorULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector


Leybold-Heraeus, #WAU500/D90A, Verti Pump System also available at additional
cost, ask about package pricing!!!


Equipped with (buyer to verify details:
   Leybold-Heraeus NT 150/360 Frequency Converter (see below for details)

GENERAL SPECIFICATIONS FOR MACHINE AS FOLLOWS:
Smallest Detectable Leak
   w/Options Quick-Test:           10-6 atm cc/sec
   w/out Quick-Test:               2x10 -10 atm cc/sec
   w/out Quick-Test w/reduced
     Pumping Speed:                2x10 -11 atm cc/sec
Full Scale Leak-Rate Meter Reading
   w/out Quick-Test:               10x10 -9 to 10x10 -6 atm cc/sec
   w/Quick-Test:                   Must multiply meter reading by correction
                                     factor (see manual Section 4-3-2)
Maximum Safe Operating Pressure
   In the Mass Spectrometer (PIII) 1x10 -4 mbar
Detectable Masses:                 3 and helium 4
Adjustable Emission Current:       0.6 to 5mA
Total Pressure Reading
   Thermovac (PII):                10 -3 to 1000 mbar
   Ionization Gauge (PIII):        10 -6 to 10 -3 mbar
Maximum Gas Flow
   @ Test Port:                    2x10 -3 atm cc/sec
Pumping Speet @ Test Port and In Mass Spectrometer
   Ultratest M2:                   For Helium 20 ltr/sec
                                   For Air 7.5 ltr/sec
   Ultratest M2DS/M2BYTC/M2BYPC:   For Helium 16 ltr/sec
                                   For Air 6 ltr/sec
Backing Pump:                      Trivac Vane Pump
   M2 and M2DS:                    D2A (2.2cfm or 1.1 ltr/sec displacement)
   M2BYTC/M2BYPC:                  D4A (4.5cfm or 2.1 ltr/sec displacement)
   Pump Vluis for Trivac:          HE-200
Diffusion Pump:                    Leybodiff 180L
   Pumping Speed For Air:          180 ltr/sec (381cfm) at 10 -5 mbar;
                                     throtted to approx. 2 ltr/sec
   Pump Fluid For Diff. Pump:      HE-300 (50cc optimum)
Cold Trap
   Capacity:                       2.4 qts of liquid nitrogen (LN2)
   Holding Time:                   Approx 20 hrs w/one Filling
Outputs - Recorder Socket But
   Pin 5 (+) to Pin 3:             0 - 10 VDC (10 VDC is full scale
                                    deflectio of leak-rate meter)
   Pin 1 (+) to Pin 3:             1 - 7 VDC in 1 volt steps corresponding
                                     to the 7 leak-rate positions on the
                                     range switch.  The output is 0 when the
                                     range switch is not in a leak-rate
                                     position.
   Triggers 1 & 2 (Optional):      6 Amp, 220 VAC max.
Mains Supply:                      115V, 60 Hz
Recommended Mains Fuse:            10 Amp
Dimensions
   PK Unit:                        22.8" x 16.3" x 16.5"
   Electronic Control Cabinet:     9.2" x 10.3" x 16.1"
   FB Remote Control Module:       8.7" x 9.1" x 5.1"
   Optional Quick-Test Housing:    8.4" x 6" x 3.2"
Weights
   PK Unit:
     Ultratest M2:                 154 lbs
     Ultratest M2DS:               165 lbs
     Ultratest M2BYTC/M2BYPC:      176 lbs
   Electrical Control Cabinet:     28.7 lbs
   FB Remote Control Module:       4.4 lbs
   Optional Quick-Test Housing:    5.5 lbs
Data for Optional Quick-Test
   Smallest Detectable Leakrate:   10 -6 atm cc/sec
   Gas Throughput in Probe:        Approx 90 atm cc/minute
   Sampled Gas Inlet to Leak 
     Detector:                     Approx 10 - 3 atm cc/sec
   Connecting Flange:              NW40KF
   Connecting Flange for 
     Calibrated Leak:              NW10KF
   Line Voltage:                   60 Hz, 220 V
   Dimensions of Housing:          8.4" x 6" x 3.2"
   Weight of Housing:              5.5 lbs
   Probe PVC Tubing
     Length:                       15' standard, up to 100' optional
   Response time for 15' tubing:   Less than 2 seconds
   Weight:                         1.1 lbs

GENERAL SPECIFICATIONS FOR FREQUENCY CONVERTER AS FOLLOWS:
Power Source
   Voltage:                        Single phase, 100/120/220/240
   Frequency:                      47-63 Hz
(Currently set up for 120V / 60Hz)
   Steady Rate Max:                680 VA
   Transient (<0.5 Sec):           750 VA
Output Values
   Voltage:                        45 Vrms
   Rated Frequency:
     TMP-150:                      840 Hz
     TMP-360:                      760 Hz
   Max. Power:
     Acceleration:                 380 Watts
     TMP-150 Normal Operation:     112 Watts
     TMP-360 Normal Operation:     260 Watts
   Relay Contacts:
     Maximum:                      24 VDC & 240 VAC @ 8 A
     Mininum:                      5 VDC @ 1 mA
Environment
   Operating Temperature Range:    0 deg to 45 deg C
   Storage Temperature Range:      -40 deg to +85 deg C
Mechanical Design
   Dimensions approx (w x h x d):  8.39" x 5.08" x 11.42"
   Weight approx:                  18.7 lbs

Ultratest Module MS:  16 1/2" x 9 1/4" x 11" 180 lbs
Ultratest PK Module:  29" x 29" x 26 1/2" 180 lbs
Quick Test Module: 7" x 6" x 8 1/2" 10 lbs
Cart For Machine: 43" x 25 1/2" x 34 3/4"  250 lbs
Wooden Box of Parts:  56 1/2" x 56 1/2" x 24 1/2" 250 lbs